Model 25360419413. 2 years old.
Had a small amount of frost on the evaporator, tested defrost thermostat and it seems to be working normally. I think the frost was a result of seal issues I had previously.
Cleaned all the frost up and tested the fresh food sensor, either I didn't get a good test or my meter is screwed, so I ordered and installed a replacement. No change. I have the dial cranked to max and it's about 40f.
In diagnostic mode, the compressor, evap fan works normally and I hear the compressor running as it should.
Freezer is -5 to -10, like the evap fan is not running long enough.
I'm thinking of spending $100 on a new control board but I thought I'd see if anyone might have any other ideas. Hate to blow $100 and have to buy a replacement anyway.
Submitted December 09, 2017 at 11:06PM by nightshifter http://ift.tt/2AHez3u appliancerepair